Sign In | Join Free | My tjskl.org.cn
China shenyang lincheng Technology Co., Ltd logo
shenyang lincheng Technology Co., Ltd
Shenyang Lincheng Electric Appliance Technology Co., Ltd.
Active Member

3 Years

Home > Wall Mounted Electric Boiler >

Wall Hung Electric Boilers For Central Heating And Hot Water 15kw 0.2Mpa

shenyang lincheng Technology Co., Ltd
Contact Now

Wall Hung Electric Boilers For Central Heating And Hot Water 15kw 0.2Mpa

Brand Name : lincheng

Model Number : LC-B-15kw

Place of Origin : Shenyang, Liaoning, China

MOQ : discussible

Price : discussible

Payment Terms : L/C, T/T

Supply Ability : 15 sets per day

Delivery Time : 3-10 working days

Packaging Details : Wooden case packaging

Rated power : 15kw

Heating area : 150-180㎡

Maximum heating pressure : 0.2Mpa

Overall dimension (L * w * h) : 360mm*170mm*630mm

colour : golden

Cross sectional area of power line : ≥10

application area : Workshops, factories, office buildings, baths, baths, household, schools, villas, hospitals

Contact Now

Wall Mounted Electric Boiler 15kW Heating Area: 150-180 ㎡ Wall Mount Enclosure

Operation Skills Of Wall Mounted Electric Boiler:

The upper and lower limit temperature and temperature difference of the wall mounted electric boiler shall be set reasonably. The working principle of the wall mounted electric boiler is intermittent operation, that is, when the water supply temperature is less than the upper limit temperature, the electric boiler is in the heating state, and when the water supply temperature reaches the upper limit temperature, the electric boiler is in the shutdown and thermal insulation state. If the upper limit temperature of the wall mounted electric boiler is set too high, it will be difficult for the actual water supply temperature of the electric boiler to reach the upper limit temperature, so that the electric boiler will be in a 24-hour heating state. Too small temperature difference makes the wall mounted electric boiler in frequent heating process. The temperature difference between the upper and lower limits is set at about 10 degrees, which is more conducive to power saving.


Wall Mounted Electric Boiler Product Parameters:

Serial number Product model Company LC-B-6kw LC-B-8kw LC-B-10kw LC-B-12kw LC-B-15kw
one Rated power KW 6 8 10 12 15
two Rated current A 27.3 36.4 45.5 48.2 52.8
three Heating area 60-80 80-100 100-120 120-140 150-180
four input voltage 50HZ 220V 220V 220V 220V/380V 220V/380V
five Minimum flow of water pump configuration L/min 15 15 20 20 25
six Hot water yield 50 ℃ L/min 5.62 3.75 4.69 5.62 6.9
seven Design thermal efficiency 98% 98% 98% 98% 98%
eight Maximum water temperature 85 85 85 85 85
nine Low temperature protection temperature 5 5 5 5 5
ten Overall dimension (length * width * height) mm 360*170*630 360*170*630 360*170*630 360*170*630 360*170*630
13 Water inlet and outlet interface DN 32 32 32 32 32

Safety Function Of Wall Mounted Electric Boiler:

1. Antifreeze protection: when the system detects that the ambient temperature is below 2 ℃, the system automatically starts heating, and stops heating when the temperature reaches a constant temperature.

2. Anti dry burning protection: when there is no dry burning in the heating system and the temperature exceeds 95 ℃, the dry burning protection device will start and automatically cut off the power supply to stop heating.

3. Overtemperature protection: when the heating temperature exceeds 95 ℃, that is, when the temperature of hot water reaches the maximum value under its control, the overtemperature protection device is started to stop further heating.

4. Overcurrent protection: when the current exceeds the set current, the equipment will automatically power off to protect the equipment.

5. Overvoltage protection: at present, the working voltage of electromagnetic boilers can basically float within 10% of the rated voltage. When the voltage is too high, the current is automatically cut off to prevent equipment damage.

6. Leakage protection: the machine is equipped with an intelligent self detection system. When the system detects leakage, the intelligent chip protection function starts and the heating power is automatically cut off.

7. Short circuit protection: it is used to protect the short circuit fault caused by the short circuit of unequal potential conductors in the power supply system.

8. Phase failure protection: in case of phase failure of line power supply, it will automatically stop operation to avoid burning accident of main electrical appliances.

9. Self inspection protection: the system built-in program performs self inspection for common faults and stops operation automatically.

10. Undervoltage protection: due to short-circuit fault and other reasons, when the line voltage drops to the critical voltage, it will prevent the equipment from burning due to overload.

From the technical point of view, the wall mounted electric boiler has the above 10 independent safety protection systems, and the safety is guaranteed. The electromagnetic boiler with reliable quality can operate safely for 20 years. If you choose the wall mounted electric boiler, you should choose a regular manufacturer. The products have passed the national 3C certification in China, and it is better to have an insurance company to underwrite them.


Product Tags:

Wall Hung electric boilers for heating

      

electric boilers for heating 0.2Mpa

      

15kw electric boilers for heating

      
Quality Wall Hung Electric Boilers For Central Heating And Hot Water 15kw 0.2Mpa for sale

Wall Hung Electric Boilers For Central Heating And Hot Water 15kw 0.2Mpa Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: shenyang lincheng Technology Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)